guaina liquida impermeabilizzante

TR-X2 DRY

Single-component, elastomeric, anti-algae polyurethane liquid waterproofing membrane. Made with non-yellowing, UV-resistant aliphatic polyurethane resins, it features high elasticity and excellent weather and traffic resistance. It is an excellent product for waterproofing terraces, roofs, walls, and various floors.

Resists water stagnation and softening at high temperatures.

  • SUPPORTS

    Tiles, concrete, fiber cement, fabrics, tiles, insulated panel, sheaths

  • APPLICATION

    Vertical and horizontal

  • SETTINGS

    Inside / Outside

  • YIELD

    70 m² / 14 liter drum

  • WATER BASED

  • SOLVENT FREE

  • ENERGY SAVING

  • EXCELLENT PERFORMANCE

guaina liquida impermeabilizzante

Specifications

REGULATION (EU) N. 305/2011 OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL
March 9, 2011

Solar reflectance index test report according to ASTM E 1980 n. 341L dated 02.08.2024

impermeabilizzazione tetti
Test Result UNI EN 1504-2 requirements
Determination of adhesion by direct traction

UNI EN 1542

Fh=2.0 MPa

 

Flexible System

≥0,8 (0,5) MPa

without traffic

 

≥0,8 (1.0) MPa

with traffic

Permeability to carbon dioxide UNI EN 1062-6 Sd co2=59.998 m

Thickness = 216 μm

μ = 277767

Sd co2>50 m
Degree of transmission of liquid water (permeability) UNI EN 1062-3 W=0.005 kg/(m² h0,5 )  w=0.1 kg/(m² h0,5 )
Degree of water vapor transmission (permeability)

UNI EN ISO 7783

Sd = 0.4476 m

Thickness = 218 μm

μ = 2053

Class I

Indicate class

Class I

  • One-component high-performance paints Base ACQUA i / BA
  • EU limit value for this product since 2010: 140 g / l
  • TR-X2 DRY contains maximum VOCs 10 g / l

NEW CEMENT-BASED SUBSTRATES:
Make sure that the surface is free from rising damp, perfectly dry, clean and well cured (at least 2 months).

WORN CEMENT-BASED SUBSTRATES:
Eliminate, if present, parts in phases of detachment and restore any imperfections with specific cement mortar.
Dust the entire surface and make sure it is free of rising damp, perfectly dry and clean.

TARED OR BITUMINOUS SHEATHES:
Wait for the substrate to fully oxidize, which varies from 3 to 6 months depending on weather conditions. Once oxidation has occurred, thoroughly clean the entire surface of dust and any residue that could compromise the paint's adhesion.

ACRYLIC SHEATHES:
On damaged sheaths, eliminate parts in phases of detachment.
Dust the entire surface and make sure it is free of rising damp, perfectly dry and clean.

  • Make sure the substrate is perfectly prepared.
  • Apply two, three coats of TR-X2 DRY diluted 0 - 10% with water, with intervals of approximately 6 - 8 hours from each other.
  • In special cases, where a greater thickness is required, the product can be used without any dilution.

White - Gray 7047 - Transparent

  • If necessary, dilute the product in the percentages indicated to facilitate application and extension.
  • Mix well before use;
  • For a uniform finish use bases from the same production batch.
  • In case this is not possible to mix the various productions together in order to avoid any differences in tone;
  • Do not apply with a thickness greater than 800 µ (0.8 mm) per coat.
  • Do not apply with air and / or substrate temperatures below + 8 ° C or above + 35 ° C;
  • Do not apply with relative humidity higher than 80%;
  • Do not apply on substrates with rising damp;
  • Do not apply on surfaces exposed to direct sunlight;
  • Do not apply in anticipation of rain;
  • Do not interrupt the application if the surface is not completed;
  • Store the product without dilution water in a sealed container placed in a cool, dry place away from heat sources.

To obtain a surface with greater resistance to walking and with better qualities of the waterproofing mantle, a glass fiber reinforcement must be inserted between the first and second coat of the product. It is necessary to impregnate the reinforcement with TR-X2 DRY, diluted with about 30% of water by volume, in order to facilitate adhesion with the first layer of the product.
To obtain an even more resistant covering, double reinforcement in cross arrangement can be used.

Sufficiently ventilate the room after painting before staying there again.
Dispose of empty containers according to local regulations.
For further information consult the relative safety data sheet.

The information contained in this sheet is only the result of the knowledge available at the date of the same by the manufacturer.
No responsibility is assumed for damage to persons or property resulting from improper use of this information.
The manufacturer reserves the right to change the data without notice.